Content Training Methodology
Introduction

A sudden loss of power will disrupt most business operations and could lead to a company being unable to trade.

Where a company regards electrical power as critical then there will be a need for a continuous or back up power system. The installation of a UPS will provide the necessary continuity. There are however problems with these installations when there is a need for maintenance especially the use of by-pass. Power Quality compatibility problems may cause failure, which was the reason for the original UPS installation.

Seminar Objectives

The seminar is intended to develop knowledge of the need for a UPS, types available, UPS components, batteries, generators and maintenance.

Training Methodology

The seminar is conducted as modular lectures with encouragement for the delegate to interact. Case studies are included to illustrate how the UPS can provide reliability and create possible problems when not installed and maintained correctly.

Questions are welcome throughout the course and during the break sessions.

Organisational Impact

Delegates will return to their organizations equipped with new knowledge and skills that will enable them to understand more fully the requirements, roles and maintenance of UPS and battery systems.

Your standby and backup systems can be refined to ensure maximum resilience at minimum cost.

Personal Impact
On successful completion of this course, delegates will:
  • Understand the basis for the use of a UPS

  • Understand Critical Load Applications

  • Have an appreciation of Power Problems

  • Be able to review the installation and maintenance requirements of a UPS and Stand-by power installation

  • Be able to improve reliability by improving the resilience of an electrical installation

Competencies Emphasized
This programme aims to enable participants to develop the following competencies:
  • Understanding of the reasons for, and benefits of, a UPS and its battery system.

  • Understanding how a UPS works.

  • Analysis of critical loads and the benefits of supporting them with a UPS.

  • Power Quality analysis; maintenance of electrical installations.

  • Understanding of resilience and reliability issues relating to power quality.

Who Should Attend?

This seminar is directed at electrical technicians, electrical supervisors, maintenance professionals and electrical engineers who would like to expand their knowledge of UPS systems.

Programme Outline
Day 1 – Introduction to the Resilient SystemA sudden loss of power causes disruption to any business where there is no stand-by or safety service, the course introduces the term resilience.

Introduction
Regulations
Critical loads
Purpose of an Installation
Compatibility
Protection and Devices
UPS or Generator
Maintenance

Day 2 – What is a UPS?After identifying an item of load is critical then there is a need to protect or back-up the supply, a UPS is a solution.

UPS Rating
Parallel systems
What is available
Maintenance by-pass
Off Line systems
Redundancy
On Line systems
Interactive systems

Day 3 – UPS ComponentsHow does it work? A question often asked and in this module the method of operation is examined.

Transformer methods
Harmonics
Invertors
Twelve pulse rectifier
Phase control
Power factor
Six pulse rectifier
Static switch

Day 4 – BatteriesBatteries are essential as an alternative store of energy providing the reserve power needed by the UPS after a mains failure. They are also dangerous especially during installation and maintenance.

What is a battery?
Storage and Care
VLRA
Choosing a battery size
Size and location
Charging
Configuration
Battery safety

Day 5 – Generators and Site PlanningIf a power failure exceeds the reserve battery capacity the system will fail but using a generator will ensure continuous power. Planning the site and considering the load will ensure a successful installation and careful maintenance planning will ensure reliability.

Do I need a Generator?
Environmental Constraints
Mains failure
Monitoring power
UPS Compatibility
Installing the UPS
Generator size considerations
Maintaining the UPS

Copy course link
Send me course brochure
Download course brochure
Re-call me
Course inquire
Tailored Courses
Send to Friend
Group Offer
print
Register for this course

Another durations and cities for the same course

Courses Filter

City

DUBAI (UAE)
Kuala Lumpur (Malaysia)
Amman (Jordan)
Jakarta (Indonesia)
Sharm ElShaikh (Egypt)
Amsterdam (Netherlands)
Casablanca (Morocco)
Paris (France)
Istanbul (Turkey)
Singapore (Singapore)
Manama (Bahrain)
Washington (US)
Beirut (Lebanon)
Barcelona (Spain)
Kuwait (Kuwait)
Budapest (Hungary)
Athens (Greece)
Copenhagen (Denmark)
Berlin (Germany)
Brussels (Belgium)
Bucharest (Romania)
Zurich (Switzerland)
Hamburg (Germany)
Moscow (Russia)
Marrakesh (Morocco)
Beijing (China)
Doha (Qatar)
Bangkok (Thailand)
Muscat (Oman)
Toronto (Canada)
Cyprus (Larnaka)
Cairo (Egypt)
Madrid (Spain)
London (UK)
Jeddah (Saudi Arabia)
Stockholm (Sweden)
Geneva (Switzerland)
Vienna (Austria)
Munich (Germany)
Prague (Czech Republic)
Rome (Italy)
Hong Kong
Dublin (Ireland)
Dammam (Saudi Arabia)
Auckland (New Zealand)
Abha (Saudi Arabia)
Trabzon (Turkey)
Abu Dhabi (UAE)
Florence (Italy)
Tunisia
Marbella (Spain)
Riyadh (Saudi Arabia)
New York (US)
Tbilisi (Georgia)
Kiev
Frankfurt (Germany)
Malaga (Spain)
Yerevan (Armenia)
Baku (Azerbaijan)
Zagreb (Croatia)
ONLINE
Hurghada (Egypt)
Results --->  Of Courses
Download result list
32

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-04-22 2024-04-26
Offline 5450 €
Brussels-(Belgium)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-04-22 2024-04-26
Offline 5450 €
Zurich-(Switzerland)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-05-13 2024-05-17
Offline 5450 €
Amsterdam-(Netherlands)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-05-20 2024-05-24
Offline 4950 €
Yerevan-(Armenia)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-06-10 2024-06-14
Offline 4950 €
Tbilisi-(Georgia)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-06-10 2024-06-14
Offline 5950 €
Singapore-(Singapore)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-06-10 2024-06-14
Offline 5450 €
Paris-(France)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-06-17 2024-06-21
Offline 5450 €
Vienna-(Austria)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-06-17 2024-06-21
Offline 5450 €
Stockholm-(Sweden)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-07-08 2024-07-12
Offline 5450 €
Copenhagen-(Denmark)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-07-08 2024-07-12
Offline 5450 €
Cyprus-(Larnaka)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-07-15 2024-07-19
Offline 5450 €
Frankfurt-(Germany)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-07-15 2024-07-19
Offline 5450 €
Marbella-(Spain)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-07-21 2024-07-25
Offline 3450 €
Doha-(Qatar)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-07-22 2024-07-26
Offline 5450 €
Geneva-(Switzerland)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-07-22 2024-07-26
Offline 2950 €
DUBAI-(UAE)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-08-05 2024-08-09
Offline 5450 €
Prague-(Czech-Republic)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-08-19 2024-08-23
Offline 4950 €
Baku-(Azerbaijan)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-08-25 2024-08-29
Offline 2950 €
Amman-(Jordan)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-08-26 2024-08-30
Offline 5450 €
London-(UK)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-09-02 2024-09-06
Offline 5450 €
Malaga-(Spain)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-09-09 2024-09-13
Offline 5450 €
Copenhagen-(Denmark)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-09-09 2024-09-13
Offline 5450 €
Auckland-(New-Zealand)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-09-16 2024-09-20
Offline 5450 €
Florence-(Italy)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-09-29 2024-10-03
Offline 2950 €
Hurghada-(Egypt)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-10-06 2024-10-10
Offline 2950 €
Sharm-ElShaikh-(Egypt)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-10-07 2024-10-11
Offline 5450 €
Hamburg-(Germany)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-10-07 2024-10-11
Offline 4950 €
Bangkok-(Thailand)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-10-14 2024-10-18
Offline 4450 €
Trabzon-(Turkey)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-10-14 2024-10-18
Offline 5450 €
Rome-(Italy)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-10-21 2024-10-25
Offline 4950 €
Bucharest-(Romania)

UPS Systems & Battery Chargers: Maintenance & Troubleshooting

2024-10-28 2024-11-01
Offline 3950 €
Jakarta-(Indonesia)

Other courses from the same category

Registration Form

Inquiry Form

A tailored course application form

Brochure Request Form

Send to a Friend

Sample contact me back

Group Offer Form

Scandinavian Academy for Training and Development AB

Training services provider in the Kingdom of Sweden
Registration number : 7431 - 559173

Copyright © 2023 - All Rights Reserved to the Scandinavian Academy for Training and Development AB